UPS | UAT MTP
Close

UPS

6,800.00$

An MTP UPS  is an electrical device that provides emergency power to a load when the input power source or mains power fails.

It typically consists of a battery backup, surge protector, and inverter circuitry. MTP UPS systems are used to protect critical equipment and systems from power interruptions, allowing them to continue functioning during power outages or fluctuations.

They are commonly employed to safeguard computers, servers, networking equipment, telecommunications devices, and other sensitive electronics that require continuous operation without disruption.

UPS units come in various sizes and configurations to meet different power needs, ranging from small desktop models for personal computers to large industrial systems for data centers and telecommunications infrastructure.

UPS Data Sheet 

For Reference Pictures please visit our Gallery Folder,

To Order this product or any other so please Contact us and please follow our social media platforms FacebookInstagramLinkedInTwitter, and YouTube, for any future updates or queries.

Category:

Description

UPS 

MTP-3000-200W30H is CPU digital controlled true sine wave DC/AC inverter. It is designed to achieve the target of energy conservation and possesses both UPS and energy saving modes. These 2 modes are user adjustable. The unit will be factory set in the UPS mode. Depending on weather and utility conditions, users can manually adjust (refer to section 5.3) or use the monitoring software to switch to the energy saving mode.

The main difference between the UPS and Energy saving mode is the amount of energy conserved. Under the UPS mode, the unit will remain in the bypass mode as long as utility is available, thus less energy is conserved (refer to figure 4.1 for details of UPS mode control logic). Under the Energy saving mode, the priority of input source chosen is solar panel to AC utility to battery. If available, the CPU will automatically select external solar panel as its first priority in order to conserve energy.

In case of insufficient solar power and utility failure, battery power will be drawn as the last the last resort. When the capacity of batteries drops to around 10~20%, the CPU will remind the end user by continuously sending out warning siren until the system shuts down.

Features

. True sine wave output (THD<3%)
. 3000W rate output
. 500A/12v Battery
. High surge power up to 6000w
. UPS mode and energy saving mode(selectable)
. Utility<–>inverter transfer time < 10ms(Typ)
. High efficiency up to 92%
. Output voltage/frequency selectable
. Power ON-OFF switch
. Complete protections for both the input and output
. Battery low alarm and indicator
. Standby saving mode can be selectable
. Front panel LED indicator for operation status
. Full digital controlled with digital display
. Thermostatically controlled cooling fan
. Protection Bat low alarm/ Bat low shutdown/ Over voltage/ Over temp/ Output short/ input polarity reverse/ Over load/ AC circuit breaker
. Built in solar / AC charger
. Computer-based monitoring software
. Dimension: 72(W)x43(D)x153(H)cm
. 2 years warranty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front Panel

A: POWER ON/OFF switch: The inverter will turn OFF if the switch is in the OFF position.

B: AC OUTPUT outlet: To satisfy demands of different geographic areas all over the world, there are many optional AC outlets to choose from. (A & B types are standard; C, D, E, F types are optional)

C: No fuse breaker with reset button (for AC input): Under “bypass mode”, when the AC output is shorted or the load current exceeds the rated current of the No Fuse Breaker, the Breaker will open and that stops bypassing energy for the utility thus prevent possible danger. When the abnormal condition is cleared, the user can press down on the reset button to resume operation.

 

D: No fuse breaker with reset button (for receptacle): The AC output outlet has a current rating of 15A. When the load current exceeds 15A, the Breaker will open and that stops AC provision from the outlet. For application requiring more than 15A, please use the internal terminal block behind the front panel (refer to section 3.2).

E: LED indication panel: Operating status, load condition, battery low, and all types of warning will be displayed.

F: Function setting: Operating mode, output voltage, frequency, and standby saving mode can be set through this button.

G: Communication port: For remote monitoring purpose, the unit can be connected to a PC through this communication port by using the cable and monitoring software. Also for remote control purpose, the unit can be connected to the IRC module through this port.

H: Ventilation slits: The inverter requires good ventilation for proper operation and prolonging its lifetime.

I: Frame ground (FG).

J: Grommet hole for input AC utility connection.

K: Grommet hole for output AC connection.

Benefits,

The benefit of the energy-saving mode is that solar energy can be captured and stored in a battery bank for conversion into AC power with just the addition of solar panels. The user can now obtain energy without depending on AC mains. All of the required free electricity can be produced from the sun. Energy-saving mode is appropriate for places like mountain tops, boats, and automobiles where AC utility is not easily accessible. Solar energy will always be the primary source of electricity, even with AC utility accessible; AC utility will only be used as a backup as needed. Energy conservation is achieved by reducing the amount of paid electricity used in this type of design.

Useful Points,

MTP is a manufacturer of Traffic Products and Smart Traffic Cameras & Radars.

MTP offers you a wide range of Traffic-Related Products, One stop solution for engineering, electrical, electronic, and technological needs,

To Order this product or any other so please Contact us and please follow our social media platforms FacebookInstagramLinkedInTwitter, and YouTubefor any future updates or queries.

Leave a Reply

Your email address will not be published. Required fields are marked *

© 2024 UAT MTP | WordPress Theme: Annina Free by CrestaProject.